TNB Thermocouple Catalog Page

Newbury Nozzle Style Thermocouples
(Series TNB)

Ordering Information

Configure this style to request a quote or call for assistance

Part No.:

select options

Start Here

1
Series
2
Calibration
3
Sheath Diameter
4
Sheath Configuration/
Cap Size
5 6
Insertion Length
7
Junction
8
Lead Wire Material
9
Lead Wire Length
10
Termination Style
11
Special Features
TNB J H Y 001A G F A 02

2 Calibration
J Type J

3 Sheath Diameter
H 0.125" (3.2mm) (1/8")
  Sizes for reference only (Standard tolerances apply)

4 Sheath Configuration/Cap Size
Y 90 Degree bend

5 6 Insertion Length
1

7 Junction
G Grounded (standard)

8 Lead Wire Material
F 24 AWG Fiberglass with stainless steel braid (800°F)

9 Lead Wire Length
12-999
  Over 999" contact factory

10 Termination Style
A 2" stripped leads (bare ends)

11 Special Features
02 1.5" long strain relief spring

Direct OEM replacement. Type J thermocouple is held in place with a set screw. 1/8” diameter probe with a 90 degree bend and strain relief spring.