Fixed Depth Bayonet Thermocouples
(Series TA3)
Ordering Information
Configure this style to request a quote or call for assistance
Part No.:
select options
Start Here
1 Series |
2 Calibration |
3 Sheath Diameter |
4 Sheath Configuration/ Cap Size |
5 6 Insertion Length |
7 Junction |
8 Lead Wire Material |
9 Lead Wire Length |
10 Termination Style |
11 Special Features |
---|---|---|---|---|---|---|---|---|---|
TA3 |
2 | Calibration |
---|---|
J | Type J |
K | Type K |
T | Type T |
E | Type E |
3 | Sheath Diameter |
---|---|
H | 0.125" (3.2mm) (1/8") |
L | 0.188" (4.8mm) (3/16") (standard) |
Sizes for reference only (Standard tolerances apply) |
4 | Sheath Configuration/Cap Size |
---|---|
P | Straight w/ 7/16” Single slot cap |
Q | 45 Degree w/ 7/16” Single slot cap |
R | 90 Degree w/ 7/16” Single slot cap |
5 6 | Insertion Length |
---|---|
2-72 |
7 | Junction |
---|---|
G | Grounded (standard) |
U | Ungrounded |
W | Grounded (Dual Junction) |
Y | Ungrounded Common (Dual) |
6 | Lead Wire Material |
---|---|
A | Fiberglass (800°F) |
B | Fluoropolymer (400°F) |
C | Polyimide (500°F) |
F | Fiberglass with stainless steel braid (800°F) (standard) |
G | Fluoropolymer with stainless steel braid (400°F) |
H | Fiberglass with armor cable (800°F) (standard) |
J | Fluoropolymer with armor cable (400°F) |
K | Polyimide with armor cable (500°F) |
M | Fiberglass with stainless steel braid with armor cable (800°F) |
W | Fluoropolymer with stainless steel braid with armor cable (400°F) |
Wire gauge determined by ECS based on sheath diameter |
9 | Lead Wire Length |
---|---|
12-999 | |
Over 999" contact factory |
10 | Termination Style |
---|---|
A | 2" stripped leads (bare ends) |
B | 2" stripped leads w/ spade lugs |
C | Standard male plug (400°F) |
D | High temp male plug (660°F) |
E | Max temp male plug (800°F) |
G | Solid pin plug |
J | Miniature plug (400°F) |
N | Standard 3 pin plug w/ ground wire (400°F) |
P | Dual molded male plug (400°F) |
W | 2” stripped leads w/ pin terminals |
Q | 2” stripped leads w/ wire ferrules |
X |
Extra long lead wire length (beyond 2” stripped leads) |
11 | Special Features |
---|---|
None | |
01 | Solid conductor (Lead wire) |
02 | 1.5" long strain relief spring |
03 | 1.5" long heat shrink where wire exits the probe |
04 | Flat tip probe |
05 | Drill point tip |
06 | Epoxy seal |
07 | Cable Clamp |
08 | Bx Connector |
09 | Mating connector |
11 | International IEC 584-3 color coded leads |
12 | British color coded leads |
13 | German color coded leads |
14 | Japanese color coded leads |
15 | Reverse polarity color coded leads |
16 | French color coded leads |
18 | Moisture protection boot on connector |
21 | Fluoropolymer coated armor cable |
- 20 AWG stranded wire comes standard for 0.156" and larger
- 24 AWG stranded wire comes standard for 0.125" and 0.118"